Finding The Perfect Solution For Faulty Connections

Are you searching for the perfect solution for faulty connections? Then you should take help of professional thermographs. These professionals use a procedure to measure the change in surface temperature or weak or faulty installations.

Known as thermal imaging in Melbourne this process takes help of infrared to detect the mismatch of temperature and spot the problem within short time. As a result, the high-tech tool safeguards the businesses or industries from massive accidents or loss.

How the process works?

This is no doubt a better technology is widely used to detect the faults with efficacy. The thermal imaging process compares the energy level of the surfaces and gives a reading on the monitor. The difference of temperature signifies that something is going wrong in the connection or in the operation.

Where is it used?

This process has an intensive use in electrical connectivity. It is used during voltage switch gear installation, installation of cable boards or over head wires. It is also used in fuse boxes, in electrical machines, transformers, etc.

This process is used

• During installation to find out errors or possible malfunctions in the installations

• During the periodic maintenance of the installations

• During minute faults/ errors

The repair priority criteria

Based on the reading on the monitor, professionals need to understand how and when the repair needs to be done. Accordingly, 5 priority measures are indicated:

Priority 0

In this segment if the temperature differenceis 10F or less than that. It implies that the connectivity needs no repairment measures as of now.

Priority 1

In the priority 1 level (10F to 20F), the repairment or corrective measure needs to be taken, but during the next maintenance cycle. 

Priority 2

The priority 2 (temperature difference is 20F-30F) implies that corrective measures are required as per the scheduling permits.

Priority 3

In the priority 3 (temperature difference 30F-100F), you need to take corrective measures as early as possible. 

Priority 4

This is high risk zone (temperature difference more than 100F). In the priority 4 zone, immediate action should be taken to prevent any possible accidents/ damage.
Who can do the work?

For conducting the procedure, skilled and trained individuals are required. The service provider should follow the rules/ standard of the industry during conducting the work.
How risks can be avoided?

The prime focus of using this technology is to avoid possible risks in the industry. Risks, like fire break, accidents or sudden failure of electrical connectivity, can lead to severe loss for a business’ performances as well as reputation. Early detection of such risks can avoid further discontinuation of workflow and protect the employees.